10'' Touch Screen Multi Parameter Monitor SF10C

SKU: 800267

Price:
Sale price$856.99

Description

10.I inch TFT display,wide viewing angle.

Touch screen operation,which improves the working efficiency for medical staff.

Suitable for adult,pediatrics and neonate patients.

PVI ( Pleth Variability Index )

USB support PDF file export

Central station support Nurse Call by wire / wireless network.

Digital Spo2 with excellent performance.

Unique human voice alarm720 hours trend data and 12 hours of all waveforms.

 Wire and wireless network.

16 languages:English,French,German,Spanish, Portuguese ,Russian etc.

ECG

Lead mode:5 Leads, I, II, III, AVR, AVL, AVF, V

Gain:0.25, ´0.5, ´1, ´2

Heart rate:

Adult:15 ~ 300 bpm

Neonatal/Pediatric:15 ~ 350 bpm

Accuracy:1%

Resolution:1 bpm

Sensitivity:> 200 μV P-P

Differential Input Impedance:> 5 M ohm

Electrode offset potential:300mV

Leakage Current:< 10 μA

PACE pulse detect 

Range:±2±700mV

Width:0.12ms

rise time:10100µs

PACE pulse rejection

Range:±2±700mV

Width:0.12ms

rise time:10100µs

ST measurement

Range;-2.0 ~ +2.0 mV

Accuracy:-0.8mV+0.8mV:

±0.02mV or ±10%, which is greater

Respiration

Method:Impedance between RA-LL or RA-LA

Differential Input Impedance:>2.5 M ohm

Respiration Impedance Range:0.3~3Ω

Base Impedance Range:200Ω-2000Ω

Bandwidth:0.3 ~ 2 Hz

Gain:×0.25,×0.500,×1,×2,×4

Respiration Rate

Measurement Range

Adult:0 ~ 120 BrPM

Neonatal / Pediatric: 0 ~ 150 BrPM

Resolution: 1 BrPM

Accuracy

06 BrPM: unspecified

7150 BrPM: ±2 BrPM or ±2%, the greater

Inspiriting current:< 300 µA RMS max

Apnea Alarm:10 ~ 40 s

Temperature

Channel:1

Measure and Alarm Range:0 ~ 50 °C

Resolution:0.1°C

Accuracy:± 0.2℃

NIBP

Pulse Rate Range:40 ~ 240 bpm

Measure and Alarm Range

Adult Mode

SYS:40 ~ 280 mmHg

DIA:10 ~ 220 mmHg

MEAN:20 ~ 240 mmHg

Pediatric Mode

SYS:40 ~ 220 mmHg

DIA :0 ~ 160 mmHg

MEAN:20 ~ 170 mmHg

Neonatal Mode

SYS:35 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Static pressure accuracy:3mmHg

Resolution:1mmHg

Accuracy

Maximum Mean error:5mmHg

Maximum Standard deviation:8mmHg

Over pressure Protection

Adult:300 mmHg

Pediatric:240 mmHg

Neonatal:150 mmHg

SpO2

Measurement Range:0 ~ 100 %

Resolution:1 %

Accuracy

2 % for 70% ~ 100%

0% ~ 69% unspecified

Pulse Rate

Measure and Alarm Range:20~250bpm

Resolution:1bpm

Accuracy:3bpm

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Payment & Security

PayPal

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed